EasyManua.ls Logo

Manitowoc S300 - Symptom #3: Ice Machine Will Not Harvest

Manitowoc S300
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number 80-1479-3 7/10 127
SYMPTOM #3 ICE WILL NOT HARVEST, CUBES ARE NOT MELTED
YES
YES
YES
NO
NO
NO
YES
Ice Machine Will Not Harvest - Freeze Cycle is Normal and Ice Cubes are Not Melted After Harvest
Low production,
Normal fill pattern, long
harvest cycle, Possible SL #2,
Back of cubes are not melted
Discharge line temperature is normal
at the end of the freeze cycle?
S850/S1000 (A/W) = >140F/60C
All other S Models = >150F/65C
Refer to
Symptom #2
Freeze Cycle
Operational
Analysis Table
Is harvest valve energized?
Refer to Sequence of
Operation &
Wiring Diagrams
Is head pressure high &
suction pressure low
in harvest?
(Refer to Pressure Charts)
Replace
harvest
valve
Continued on Next Page...