4
WATER SERVICE/DRAINS
Water Supply
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
Water Inlet Lines
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds the maximum
recommended pressure, 5 bar (500 kPA), install a
water pressure regulator.
Install a water shut-off valve.
Drain Connections
Drain lines must have a 2.5 cm per meter drop, and
must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
!
Caution
The ice machine must be protected if it will be
subjected to temperatures below 0°C. Failure
caused by exposure to freezing temperatures is not
covered by the warranty.