22
WATER-COOLED ICE MACHINES
1. Perform steps 1-6 under “Air-Cooled Ice
Machines.”
2. Disconnect the incoming water and drain lines
from the water-cooled condenser.
3. Insert a large screwdriver between the bottom
spring coils of the water regulating valve. Pry
upward to open the valve.
4. Hold the valve open and blow compressed air
through the condenser until water no longer exits.