–103–
UG040A-261 SELF-CONTAINED AIR-COOLED — STANDARD CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest Time
Times in minutes.
Water Temperature °C
10 15 21 32
10 21.76-24.29
1.6-4.0min.
21 20.16-22.36
32 23.64-26.88
38 30.82-34.61
43 39.08-41.89