TEMPERATURE SCALE
The Temperature scale settings provide the possibility to limit the minimum
and maximum settable temperature in the working modes (Event Mode,
Constant Mode or Boost Mode).
BACKLIGHT
You can define how the backlight (blue light) of the Mapeheat Thermo Basic
is reacting. There are 3 possible settings:
Auto
The backlight is deactivated after 30 seconds of inactivity
On heat
The backlight lights up every time the thermostat is heating
Constant On
The back light does not go off
SENSOR
In the Sensor setting, you select the type of sensor that is installed. The
possible sensors are:
Factory = sensor delivered with the Mapeheat Thermo Basic





With the exception of the Factory sensor, you will be asked to give reference
points of your sensor at +15, +20, +25 and +30°C. If you do not have these
reference points of the sensor, the Mapeheat Thermo Basic is proposing you
a standard calibration of the sensor. This might not be 100% accurate but will
be close to the real values.
LANGUAGE
The Mapeheat Thermo Basic is translated into 11 languages. In this menu
you can choose to use the following languages for the firmware: Czech,
Dutch, English, Finnish, French, German, Lithuanian, Norwegian, Polish,
Russian or Swedish.
FACTORY RESET
If you need to reset all the settings to the factory settings, you can use the
factory reset.
INFORMATION
In the information section of the thermostat, you will find information on
how to contact us, on the measured temperatures and calibration and on
the software version in the thermostat.
ENGINEER SETTINGS
TEMPERATURE CALIBRATION
When running in Floor sensor mode (see Sensor setting)
You can calibrate the floor sensor to the actual floor temperature by using
the calibration menu. The floor temperature can differ from temperature
measured by the floor sensor depending on the floor construction.
When running in Room sensor mode (see Sensor setting)
You can calibrate the ambient sensor to the actual room temperature by
using the calibration menu.
The Mapeheat Thermo Basic is performing an auto calibration of the
Room Sensor after each factory reset (or after first installation). The
manual calibration of the Room sensor should only be performed after
this automatic calibration and only in the few cases where the automatic
calibration seems not to be 100% accurate.
ADAPTIVE FUNCTION
Thanks to the adaptive function, the Mapeheat Thermo Basic will know
when to switch your heating on, in order to obtain the desired temperature
at the desired time. The Adaptive function is only active in the Event Mode
and is activated from factory. You can de-activate the Adaptive function in
the Adaptive function menu.
The Adaptive function will optimize the energy consumption to the desired
comfort of the user.
SENSOR SETTING
The Mapeheat Thermo Basic can operate in different sensor settings. Some
of the settings are activated in the thermostat when a physical floor sensor is
installed; others are activated when there is no external sensor installed.
When there is a floor sensor installed and connected
Floor
The Mapeheat Thermo Basic is regulating the temperature based on the
input given by the floor sensor (embedded in the floor)
Room/limit
The Mapeheat Thermo Basic is regulating the temperature based on the
input of the room sensor (integrated in the thermostat) but is making
sure the floor is not exceeding a desired temperature measured by the
floor sensor
When there is no external sensor installed or connected
• Room
The Mapeheat Thermo Basic is regulating the temperature based on the
input of the room sensor (integrated in the thermostat)
No sensor
The thermostat works like a regulator. It will work in duty cycles and it
will activate the electrical heating cables during a percentage of this duty
cycle.