Do you have a question about the Maquet SERVO-i and is the answer not in the manual?
Oxygen Concentration | 21-100% |
---|---|
FiO2 Range | 21 - 100 % |
Power Supply | 100-240V AC, 50/60 Hz |
Type | Ventilator |
Modes of Ventilation | Volume Control, Pressure Control, Pressure Support, SIMV |
Patient Range | Pediatric, Adult |
Display | Color touchscreen |
Tidal Volume Range | 0.05 - 4.0 L |
Pressure Range | 0 to 100 cmH2O |
Respiratory Rate | 1 to 150 breaths per minute |
PEEP/CPAP | 0-40 cmH2O |
Inspiratory Time | 0.1 to 5 seconds |
Screen Size | 12.1 inch |
Inspiratory Pressure Range | 0 to 100 cmH2O |
Trigger Sensitivity | Flow or Pressure trigger |
Alarms | Comprehensive alarm system |
This section provides general information about the manual's scope and content.
Explains safety symbols and critical information for user and patient safety.
Defines common symbols used throughout the manual for clarity.
Discusses general cleaning practices and acknowledges institutional variations.
Describes wall diagrams as cleaning checklists and step-by-step instructions for poster use.
Summarizes the overall process for cleaning, disinfection, and sterilization.
Outlines the initial steps for preparing and safely dismantling the equipment.
Details the procedure for removing the expiratory cassette from SERVO-i and SERVO-s units.
Provides instructions for wiping down the device and discarding disposable parts.
Guides on rinsing parts before disinfection, offering an alternative method.
Covers methods for disinfecting parts using washer-disinfectors or chemical disinfectants.
Specific steps for using a washer-disinfector for component disinfection.
Specific steps for using chemical disinfectants for component disinfection.
Instructions for thoroughly rinsing components after disinfectant application.
Presents various methods for drying components after cleaning processes.
Information on autoclaving, cycle limits, and drying after sterilization.
Details steps for reassembling components and performing a crucial pre-use check.
Provides detailed cleaning instructions specific to the Servo Ultra Nebulizer.
Outlines the cleaning procedures for the Servo-i NAVA system.
Details the cleaning procedures for the Servo CO₂ analyzer.
Covers procedures for disinfecting and sterilizing the airway adapter.
Refers to separate manuals for cleaning specific accessories.
Recommends regular inspections and preventive maintenance by authorized personnel.
States that the O2 sensor requires no regular maintenance.
Details checking O2 cell status, exchange criteria, and related safety warnings.
Lists steps for preparing and dismantling the unit for O2 cell replacement.
Provides instructions for removing and replacing the O2 cell and bacterial filter.
Details the steps for reassembling the unit after O2 cell replacement.
Outlines procedures for extended cleaning of the inspiratory channel.
Details steps to remove and insert the inspiratory channel and associated tube.
Provides guidance on cleaning the inspiratory channel and tube.
Instructions for correctly inserting the O2 cell and O2 sensor.
Covers final assembly steps for the inspiratory channel and the pre-use check.
Provides information regarding optional accessories used for maintenance tasks.