5.4
FM
25
uS
OUTPUT
LEVEL
ADJUSTMENT
1.
Set
the
FM
signal
generator
to
provide
a
400
Hz,
50%
modulated
98
MHz
mono
signal,
at
1kuV
output.
Precisely
tune
the
tuner
to
98
MHz.
2.
Depress
the
FM
25
uS
pushswitch,
and
adjust
R216
until
the
outputs
of
both
channels
are
580
mV.
6.
VOLTAGE
CCNVERSION
FOR
EUROPEAN
MODEL
The
European
version
of
the
Model
2110
is
equipped
with
a
universal
power
transformer
that
may
be
adjusted
to
Operate
at
110V,
120V,
220
V,
or
240
V
AC
at
50
to
60
Hz.
To
convert
the
unit
to
a
different
power
source
voltage,
reposition
conversion
plug
as
shown
in
Figure
2.
CAUTION:
DISCONNECT
POWER
SUPPLY
CORD
FROM
AC
OUTLET
BEFORE
CONVERT-
ING
VOLTAGE.
FTZ
REGULATION
Instruction
for
the
use
in
the
range
other
than
specified
in
FTZ
codes.
Achtung
fir
die
Leute,
die
in
dem
Gebiet
wohnen,
wo
die
FTZ-Bestimmungen
vorherrschend
sind.
Sollte
des
Geraét
auch
fiir
Frequenzen
auszerhalb
des
in
den
FTZ-Bestimmungen
angegebenen
Bereiches
empfangebereit
sein,
bitten
wir,
den
Bereich
durch
Nachstellen
des
Kernes
in
der
Oszillatorspule
(in
der
Abbildung
mit
““FTZ’
gekennzeichnet)
so
zu
korrigieren,
dass
er
den
Bestimmungen
entspricht.