35 36
1) AM/FM Signal Generator
2) VIdeo Signal Generator
3) Digital Multimeter
4) Distortion level meter
8. TEST EQUIPMENT REQUIRED
SPK setup
Front L/R Center Surround L/R Sub Woofer
FILTER1
SMALL
100Hz 20kHz
SMALL
100Hz 20kHz
SMALL
100Hz 20kHz
ON
20Hz 100Hz
FILTER2
LARGE
20Hz 20kHz
LARGE
20Hz 20kHz
LARGE
20Hz 20kHz
ON
20Hz 100Hz
FILTER3
LARGE
20Hz 20kHz
LARGE
20Hz 20kHz
SMALL
100Hz 20kHz
OFF
-
5. How to reset the product
When the product is POWER ON, press 3 buttons [ TUNING▲+ CLEAR + MEMO ] simultaneously.
FLD shows “DEFAULT”, then all memories are cleared. And the product will be STAND-BY status.
This adjustment is normally not necessary, because the coil LA06 is preset by the original supplier
9. ALIGNMENT PROCEDURES
1. AM IF Adjustment
Step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output
Level and Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
Signal generator output to
transmission *loop antenna.
(*:Standard required loop)
1000kHz
Level 300 µV/m (50dB/m)
Mod. 400 Hz 30%
Tuning point LA06
Output level
(L or R)
Maximum
at TAPE-OUT
2. AM Tracking Adjustment
Step
**Input Signal Source
Connection
Signal
Frequency
Source Signal Output
Level and Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
Signal generator output to
transmission *loop antenna.
(*:Standard required loop)
600 kHz
Level 300 - 400 µV/m
Mod. 400 Hz 30%
LA01
Output level
(L or R)
Maximum
at TAPE-OUT
2
3
Output level
(L or R)
Maximum
at TAPE-OUT
CA01
600 kHz
(P5)
1400 kHz
(P7)
Level 300 - 400 µV/m
Mod. 400 Hz 30%
1400 kHz
Repeat step 1 and 2 until sensitivity be maximized.
3. AM auto stop Adjustment
Step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output
Level and Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
Signal generator output to
transmission *loop antenna.
(*:Standard required loop)
1000 kHz
500 µV/m (54 dB/m)
R209
"TUNED"
indicate on FLD
2 Only Confirm
1000 kHz
(P6)
AUTO
SCAN
"TUNED"
indicate on FLD
1000 µV/m (60 dB/m)
REMARK: This adjustment is related to the FM muting Level Adjustment. The FM muting Level re-adjustment is necessary
after this adjustment.
4. FM MONO. Distortion Adjustment
Step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output
Level and Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
Signal generator output to
FM antenna terminal. (75 Ω)
98 MHz
500 µV (54 dB)
MONO 1kHz /
Dev. 75kHz 100%
98 MHz
(P2)
L201
Distortion level
Minimum
at TAPE-OUT
S301
JL51JL52
J102
J501
Q201
R104
J101
Q301
JL53
JL54
JL55
LA01
A101
L201
R209
R219
R218
TV LD-INOUT-MONI.OUT DVDVCR
LA1837
NJM4558DD
PL04WG280J301-3
MW 600kHz
MW 1400kHz
CA01
ST DIST
AM TUNED
FM DIST
AM IF
LA06
FM MUT
SEP