To check if the amp is in order, switch off the unit and switch
it on again one minute later. This action will deactivate
the protection operation. If the PROT-1 (pin6) remains
"L", which constitutes an abnormality, the unit shuts down
approximately 3 seconds later and the STANDBY indicator
starts flickering.
If the protection operation will not be deactivated after the
power is turned on again, the amp circuit may be broken.
[B] The PROT-2 (pin7) is the port to detect abnormalities
of the power supply circuit.
Detection of an abnormality in the power amp power 1.
supply circuit.
This port monitors the midpoint voltage of the power amp
power supply between +48V and -48V. If the voltage at
the connection point of R801 and R802 exceeds DC
±1.2V, Q903 or Q904 will turn on to change the signal
from the PROT-2 (pin7) to L from H.
Detection of an abnormality in the preamp power supply 2.
circuit.
Q901 and Q902 monitor the midpoint voltage between
+28V and -28V. If the voltage at the connection point of
R905 and R906 exceeds DC ±1.2V, Q901 or Q902 will
turn on to change the signal from the PROT-2 (pin7) to L
from H
Detection of an abnormality in the function relay power 3.
supply circuit.
If the +24VL of the relay power supply receives an
electric current of over 80 mA, Q815 and Q901 will turn
on to change the signal from the PORT-2 (pin7) to L from
H.
If any of the above three abnormalities is detected, the signal
from the P_ON (pin15) terminal will be changed to L from
H, the power relay L852 will be turned off and the unit will
be shut down. Then, the STANDBY indicator flickers and
indicates that an abnormality has occurred.
This protection operation is intended for a breakdown of the
AMP circuit or the power supply circuit and immediately shut
s off the power in order to avoid the risk of damage.
To check if the amp circuit or the power supply circuit is
broken, switch off the power and then switch it on again
one minute later. This action will deactivate the protection
operation.
If the RPOT-2 (pin7) remains L after the power is switched on
again, the unit will be shut down again three seconds later
with the STANDBY indicator flickering.
If the unit is powered on again and yet cannot get the
protection operation deactivated, the amp circuit or the
power supply circuit may be broken.
[B] PROT-2 (pin7)は、電源回路の異常を検出するポートです
パワーアンプ用電源回路の異常を検出。1.
パワーアンプ用電源の+48V と-48Vの中点電圧を監視
し、R801とR802の接続点の電圧が約 ±1.2V(DC) を超え
ると、Q903もしくはQ904がONしてPROT-2 (pin7)が "H
→L" になる。
プリアンプ用電源回路の異常を検出。2.
Q901 とQ902 はプリアンプ用電源の +28V と -28V の
中点電圧を監視し、R905とR906の接続点の電圧が約
±1.2V(DC) を超えると、Q901もしくはQ902がONして
PROT-2 (pin7)が "H→L" になる。
ファンクションリレー用電源回路の異常を検出。3.
リレー用電源の+24VL に約80 mAを超える電流が流れる
と、Q815, Q901がONしてPROT-2 (pin7)が "H→L" にな
る。
1.〜 3. のいずれかの異常を検出すると、P_ON (pin15) を
"L→H" にして、電源リレー L852 をOFFしシャットダウンし
ます。このときSTANDBYインジケーターが点滅し、異常が起
きたことを表示します。
これは、アンプ回路もしくは電源回路の故障を想定した
PROTECTION動作で、危険回避のため即座に電源を切る動作
です。
アンプ回路もしくは電源回路が故障しているかどうかを確認す
るには、一旦電源SWを切り1分ほど待ってから電源SWを再投
入します。
この操作でPROTECTION動作が解除します。
電源SWを再投入してもPROT-2 (pin7)が "L" の異常状態の場合
は、約3秒後に再びシャットダウンしてSTANDBYインジケー
ターが点滅します。
電源を再投入してもPROTECTION動作が解除されない場合
は、アンプ回路もしくは電源回路が故障していると考えられま
す。