8
CHECK DSP
Indication is keep and sound is mute.
CHECK DSP ROM
CHECK ADC
表示状態はそのままで音声は Mute 状態
CHECK E2P I F
CHECK E2P
CHECK 2 3 2C
CHECK POW5
PROTECT
CHECK DSP
CHECK DSP ROM
CHECK ADC
CHECK E2P I F
CHECK E2P
CHECK 2 3 2C
CHECK POW5
PROTECT
5. SYSTEM ERROR
When the microcomputer detects a trouble, the following
information is displayed on the FLD.
After the error contents indication, Surround Mode is
initialized and returned Factory mode.
The contents of the ERROR indication are the followings.
1. Trouble in DSP
If communication with DSP is troubled more than 2
seconds.
5.SYSTEMERROR
製品内部での異常発生時に処理、表示を行います。主に各
Device との通信異常を検出します。
・ ERROR 表示後、SurroundMode は初期化され工場出荷
の状態に戻ります。
・ ERROR 表示の内容は下記です。
1. DSP 異常検出表示。
DSP との通信上の不具合を約 2 秒検出した時。
2. Trouble in DSP Code
The trouble of DSP Code was found.
3. Trouble in ADC
When ADC input was chosen and CAL signal continued
High about 2 seconds after the ADC Calibration start.
2. DSPCode異常検出表示。
DSPCode の異常を検出した時。
3. ADC 異常検出表示。
ADC 入力を選択した場合に ADCCalibration 開始後、
CAL 信号が約 2 秒以上 High を持続した時。
4. Trouble in EEP-ROM
If data from EEPROM does not match.
5. Trouble in EEP-ROM IF
If communication with EEPROM is troubled more than 2
seconds.
6. Trouble in RS-232C
If communication of Panja with RS232C is troubled more
than 2 seconds.
7. Trouble in 5V Supply
If 5V supply to DATA DIR is troubled.
8. Trouble in Protection
CPU turns off the speaker output.
4. EEP-ROM 異常検出表示。
EEP-ROMData の不整合を検出した時。
5. EEP-ROMIF 異常検出表示。
EEP-ROM との通信不具合が約 2 秒以上生じた時。
6. RS-232C 異常検出表示。
Panja通信時にRS-232Cとの通信不具合を約2秒以上検
出した時。
7. 5V 異常検出表示。
DATADIR. の異常を検出した時。
8. Protection 信号異常検出表示。
Speaker からを出力を止めます。