EasyManua.ls Logo

Marey ECO180 - Technical Specifications and Installation Requirements; Product Inner Structure

Marey ECO180
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
09
Height to the Ground
Sealer
Release Valve
Wash with Filer
Inlet Water
2000mm
Power
Supply
E N L
Air Switch
Fig. 03
Fig. 04
08
TECHNICAL SPECIFICATIONS
Power
Voltage
Max. Temp. Increase at 1.5 GPM
Min. Water Flow Activate Unit
Temp. Scope
Water Connections
18Kw / 61459 BTU/Hour
220V-240V / 60Hz
0.92GPM / 3.5LPM
3/4"NPT
82~127ºF
ECO180
Max. Amp. Load
75A
Min. Required Circuit Breaker Size
2x50A
Recommended Wire Size
2x8 AWG copper
Water Proof
Weight
Height x Width x Depth
13lbs / 6kg
11” x 16” x 3,5”
Ipx4
81ºF
Starting Pressure
Water Pressure
29 PSI
29 PSI - 101.5 PSI
Installation
Vertical Mounted
Control
Manual
Over-temp. Protection
140ºF
Cable
6mm²
Dry-heating Protection
203ºF +/- 37ºF
280 x 406 x 89 mm

Other manuals for Marey ECO180