2322
Trouble Possible Cause Remedy
No “CL” 
displaying.
Power outage.
Unit requires 120V power.  Use 
unit  when  power  is  restored. 
Check circuit breaker and reset if 
needed.  Check  ground  fault 
circuit interrupter (GFCI) if circuit 
includes  one  and  reset  if 
necessary.
Unit is unplugged.
Check power plug and ensure 
properly plugged. Plug the power 
plug properly.
There is no hot 
water flow when 
a hot water faucet 
is opened.
No/empty fuel source.
Water valve closed.
Power outage.
Flow is too low or 
became too low.  (less 
than 0.66 gallons per 
minute (gpm) or 2.5 
liters per minute (l/m).
Freezing 
temperatures may 
have frozen water in 
the heater or hot 
water system.
Fuel gas meter 
special control 
restrictions.
Distance from heater 
to source is long.
Fuel gas valve needs to be open.
Refill source tank (if applicable).
Open the water inlet valve.
Unit  requires  120V  power  to 
operate.
Flow  is  below  the  lower  limit 
necessary  for  stable  burner 
operation  and  proper  tem-
perature control. Increase the hot 
water flow to enable system.
See “No Flow Due to Expected 
Frozen Heater” section of this 
manual for procedure to thaw 
unit.
Some fuel gas valves may have 
special  restrictions  or  digital 
controls that use. Consult your 
gas  supplier  and/or  a  service 
professional for assistance.
Allow time for hot water to travel 
through system to reach the point 
of use.
7. Open valves V1 and V2 into the water heater.
8. Operate the pump. Circulate the cleaning solution through the water heater for at 
least 45 minutes.
9. Turn off the pump.
10.  Rinse  the  cleaning  solution  from  the  water  heater  by  closing  valve  V2  and 
opening valve V4, flow water through the heater and into a container or drain for at 
least five minutes.
11. Close Valve V1 and Open Valve V3 this places the house back online.
12. Disconnect all hoses.
13. It is also wise to clean the water inlet screen at this time. Close Valve V3 and V4 
to do so. Clean the water inlet screen and remove any debris.
14. Replace the screen and open valves V3 and V4 once more. Checks for leaks.
15. Return heater to operation by following start up instructions.
ELECTRICAL MAINTENANCE WARNINGS
    Label all wires prior to disconnection when serving controls. Wiring 
    errors can cause improper and dangerous operation. Always verify 
    proper operation after servicing.
For  operating  difficulties  with  your  unit,  please  consult  the  following  table  for 
guidance.  If  you  need  further  assistance,  call  qualified  technician.  Please  have 
product information ready when you call including serial number, date of purchase 
and error code if shown on the control panel.
Note:  Please  check  water  heater  for  an  error  code  and  respond  according  to 
recommendations found in “Error Codes” portion of this manual.