[UserLed] Section
Deprecated and used only for backwards compatibility.
Use [PlayLed] instead.
Defines the function of the front panel user LED.
UserLed Section Parameters:
Mode - User LED operating mode.
Value Function
Disabled The LED does nothing
Playing The LED will light while a track is playing (default)
Stopped The LED will light while the unit is stopped
Table 22
[PlayLed] Section
Defines the function of the play LED
PlayLed Section Parameters:
Enabled - Enable or disable play LED
Value Function
Yes The LED will light while a track is playing (default)
No The LED is disabled and will not light
Table 22
[StatusOutput] Section
Defines the function of the status output solid-state relay.
Mode - Status output operating mode.
Value Function
Disabled The status output does nothing
Playing The status output is active while a track is playing (default)
Stopped The status output is active while the unit is stopped
Table 23