1998-08-03 3Introduction
1.3 A
DDITIONAL
CAUTIONS
1.3.1 E
LECTROSTATIC
DISCHARGE
(ESD)
SENSITIVE
PARTS
The following parts are classified as ESD sensitive:
Motherboard PCB and the individual ICs.
Keyboard/display PCB and the individual ICs.
Hall-sensors.
To avoid damaging ESD sensitive parts:
Ensure that you and your tools have the same potential (ground) as the fixture before and when handling any of the above
components.
Always store PCBs in antistatic (electrically conducting) bags and store ICs in antistatic foam.
Always power off the fixture, and allow capacitors do discharge before removing or inserting any components on the PCBs.
1.3.2 I
NDUCTIVE
LOADS
Always power off the MAC 500 before connecting or disconnecting any of the step motors. Otherwise, damage to the motor
drivers may occur.
1.4 S
ERVICE
MATERIALS
AVAILABLE
FROM
M
ARTIN
1.4.1 P
ROTECTION
DEVICES
UV protection glasses, clear .....................................................................................................402010
ESD table mat, 750 x 610 mm...................................................................................................402020
Snap button connector, female, type 4730, for ESD table mat....................................................402022
ESD ground (earth) wire w/2 banana sockets, 4710 ..................................................................402023
Adjustable ESD wrist band........................................................................................................402024
Spiral wire for ESD wrist band...................................................................................................402025
Antistatic bag, 200 x 300 mm....................................................................................................453801
Antistatic bag, 100 x 125 mm....................................................................................................453802
1.4.2 T
OOLS
2 mm T-shaft allen key ..............................................................................................................402001
ESD IC pin straightener combi..................................................................................................402030
Light duty maintenance tool for AMP MTA 100 sockets..............................................................402011
Heavy duty pistol grip for AMP MTA 100 sockets (requires head, below)....................................402012
Heavy duty termination head for AMP MTA 100 sockets (requires grip, above)...........................402013
1.4.3 L
UBRICANTS
High temperature synthetic oil, 0.5 liter .....................................................................................400003
Silicone lubricant, 0.5 liter.........................................................................................................400119
Silicone lubricant, 0.2 liter in dispenser with closable valve .......................................................400118
1.4.4 A
DHESIVES
High temperature (300 - 375° C) silicone glue, red ....................................................................400002
Loctite 243 thread lock, 10 ml ...................................................................................................400531
Loctite 290 thread lock, 10 ml ...................................................................................................400533

Other manuals for Martin MAC 500