41
lower mark lines If it is below the lower one distilled
water shall be added to the battery. After filling in
distilled water, measure the voltage of the negative pole
with a voltmeter; if it is less than 12V, recharge it with a
charge power supply.
Seriously corroded conductor connectors of the battery
shall be replaced.
Installation of accumulator
Installation is in the reverse order of removal. While
connecting the poles, connect the positive pole first.
Caution
1 In this model, both the startup and EMS system
are completely powered with accumulator.
Therefore, it is quite important to ensure sufficient
electric quantity of accumulator, otherwise, startup
is impossible.
2 Never fill in tap water, because this will shorten the
accumulator’s life span.
3 To dismantle battery ,disconnect the
negative(-)electrode before the positive(+)one,
and vice versa in installation .Ensure against any
contact of the positive(+)electrode with the vehicle
body.
4 Never have the electrolyte level come over the
upper mark line when adding distilled
water .Otherwise overflow and corrosion will occur.
5 The electrolyte contains sulfuric acid and will
cause serious hurt to skin and eyes by contact. In
case of contact with it, wash it off for 5 minutes and
see a doctor immediately.
Negative (-) Connector
Positive (+Connector

Table of Contents