9.15 Limit values for the pump
The pump’s maximum speed, maximum pressure and maximum temperature are included in the technical
data sheet supplied with each pump. These limit values must not be exceeded in any circumstances. This
applies in particular when using a frequency converter.
If pump is supplied without a drive, the following values apply:
C100 C200 C250 C300 C400 C500 C600
Maximum
pressure*
10 bar/
145 psi
10 bar/
145 psi
15 bar/
217 psi
15 bar/
217 psi
15 bar/
217psi
15 bar/
217psi
15 bar/
217psi
Maximum speed* 1000rpm 1000rpm 800rpm 600rpm 600rpm 600rpm 600rpm
Maximum
temperature*
100C/
212F
100C/
212F
100C/
212F
100C/
212F
100C/
212F
100C/
212F
100C/
212F
Minimum
temperature*
-20C/-4F -20C/-4F -20C/-4F -20C/-4F -20C/-4F -20C/-4F -20C/-4F
* These limits may vary, depending on the drive, the application and the rating of the pump. (See your
purchase order confirmation, or contact MasoSine and quote your pump’s serial number.) On customer
request, higher pressures and temperatures are possible.
9.16 Maintenance and repair
Maintenance and repair work on the pump should only be carried out by trained service personnel, who
should have read and understood this manual prior to installing, operating or servicing this equipment.
Inform operating personnel before starting maintenance and repair work. Protect all plant parts and
operating media connected before and after the machine, such as compressed air and hydraulics, against
unintentional start-up. In all maintenance, inspection and repair work, switch the machine off and secure
the main switch against unintentional start-up.
Secure larger assemblies carefully to lifting gear. Check loosened screw connections for firm seating. Use
only original spare parts.
After maintenance work is finished, check the safety devices are functioning.
Bearings maintenance
Note: Remove the bearing housing only to replace or adjust the shim ring. Do not attempt to
dismantle the power end of the pump or replace the bearings. Pumps needing repair, servicing,
new bearings or other work on the power end must be returned to MasoSine for attention. Special
training is available. Please contact MasoSine for further information.
Certa C100/C200/C250/C300/C400 bearing replacement intervals:
The table below shows the recommended intervals in hours, for renewing the bearings subject to the
maximum speed and pressure, as listed in the table See Limit values for the pump above
Certa pump model Bearings maintenance interval
C100 10,000 hrs
C200 10,000 hrs
C250 10,000 hrs
C300 10,000 hrs
C400 10,000 hrs
Certa C500 bearing replacement intervals:
We recommend renewing the bearings of Certa500 pumps after running for the periods shown in the
table below.
200 rpm 400 rpm 600 rpm
5 bar 10,000 hours 10,000 hours 10,000 hours
10 bar 10,000 hours 10,000 hours 10,000 hours
15 bar 10,000 hours 9.000 hours 6.000 hours
CertaC600 bearing replacement intervals:
We recommend renewing the bearings of Certa600 pumps after running for the periods shown in the
table below.
200 rpm 400 rpm 600 rpm
5 bar 10,000 hours 10,000 hours 10,000 hours
10 bar 10,000 hours 10,000 hours 10,000 hours
15 bar 10,000 hours 10,000 hours 7.500 hours
m-certa-en-08 9