Thank you for purchasing a MS5308 LCR digital bridge meter.
The MS5308 LCR digital bridge meter is a professional
instrument for measuring inductance, capacitance and resistance.
It has many features, such as automatic identification, automatic
measurement range, high measurement accuracy and speed, wide
measuring range and so on.
An ordinary multimeter only provides DC mode for resistance
measurement, while the MS5308 provides both AC and DC
measurement modes. A variety of test frequencies up to 100Khz
can be provided for inductance, capacitance and resistance in AC
mode to meet the actual needs better.
Correct usage can ensure that the instrument will work precisely
for a long time. Please read the instructions carefully before using
and operate the instrument strictly in accordance with the
instructions .
1.1
Panel description
1
Display
2
Functional buttons area
3
Power switch
4
IR Port
5
External power port
6
Calibration button port
7
DUT + jack
8
DUT - jack
9
Shielding grounding jack
1.2
Inspection
When you get a new LCR meter, please check the instrument and
its accessories. If something is damaged or missed, please contact
the store you bought the instrument from for adjustment or
replacement.
1.3 Accessories
MS5308 LCR digital bridge meter Kelvin test clip (one pair)
SMD test probe IR data line
Upper computer program CD External power supply

Other manuals for Mastech MS5308

Question and Answer IconNeed help?

Do you have a question about the Mastech MS5308 and is the answer not in the manual?

Mastech MS5308 Specifications

General IconGeneral
ModelMS5308
DisplayLCD
Resistance Range400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ
Diode TestYes
Continuity TestYes
Data HoldYes
BacklightYes
Auto Power OffYes
Power Supply9V Battery
DC Voltage Range400mV/4V/40V/400V/600V
AC Voltage Range4V/40V/400V/600V
DC Current Range400μA/4000μA/40mA/400mA/10A
AC Current Range400uA/4000uA/40mA/400mA/10A
Capacitance Range40nF/400nF/4μF/40μF/400μF/4mF/40mF
Inductance Range40mH/400mH/4H/40H
Frequency Range10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz
Operating Temperature0°C ~ 40°C

Summary

General Instructions

Panel Description

Details the physical layout and components of the MS5308 LCR digital bridge meter's front panel.

Inspection

Guidance on checking the LCR meter and its accessories for damage or missing items upon receipt.

Accessories

Lists the standard accessories included with the MS5308 LCR digital bridge meter.

Safety Instructions

Description

Definition Description

Explains common abbreviations and terms used in the MS5308 LCR meter's operation and display.

Impedance Parameter Description

Details the impedance parameters (Z, Rs, Xs, θ) and their measurement context for the LCR meter.

Series-Parallel Connection Mode Description

Functional Characteristics Description

Meter Probe Measurement

Measurement Operation Description

Automatic Measurement

Describes the meter's automatic identification mode for measuring L, C, or R values.

Single Measurement

Details how to perform single measurements for L, C, R, or DCR modes.

Comparison and Selection

Explains the process of comparing measured objects and selecting acceptable ones.

Deviation Proportion Measurement

Details how to measure and display the deviation proportion (REL%) of a component against a reference.

Data Hold Function

Explains how to use the Hold button to freeze and display the current measurement value.

Additional Functions

Auto Power Off Function

Describes the automatic power-off feature to conserve battery life after a period of inactivity.

Backlight Function

Details the operation of the display backlight, including automatic turn-off.

Battery Power Detection Function

Explains the meter's capability to detect and display battery power levels.

Upper Computer Software Installation

Related product manuals