3.2.4
3.2.4
3.2.4
3.2.4 Continuity
Continuity
Continuity
Continuity Check
Check
Check
Check
To
To
To
To avoid
avoid
avoid
avoid electrical
electrical
electrical
electrical shock
shock
shock
shock and/or
and/or
and/or
and/or damage
damage
damage
damage to
to
to
to the
the
the
the
instrument,
instrument,
instrument,
instrument, disconnect
disconnect
disconnect
disconnect circuit
circuit
circuit
circuit power
power
power
power and
and
and
and
discharge
discharge
discharge
discharge all
all
all
all high-voltage
high-voltage
high-voltage
high-voltage capacitors
capacitors
capacitors
capacitors before
before
before
before
testing
testing
testing
testing for
for
for
for Continuity.
Continuity.
Continuity.
Continuity.
Continuity is a complete path for current flow.
The beeper sounds if a circuit is complete. These brief
contacts cause the Meter to emit a short beep.
To
test for continuity:
1. Set the rotary switch to range.
2. Press the /
/
/
/ key to activate Continuity Check.
3. Connect the black and red test leads to the COM and
terminals respectively.
4. Connect the test leads to the resistance in the circuit
being measured.
5. When the test lead to the circuit is below 50 , a
continuous beeping will indicate it.
Note:
Note:
Note:
Note:
¥ Continuity test is available to check open/short of the
circuit.
3.2.5
3.2.5
3.2.5
3.2.5 Capacitance
Capacitance
Capacitance
Capacitance measurement
measurement
measurement
measurement
To
To
To
To avoid
avoid
avoid
avoid electrical
electrical
electrical
electrical shock
shock
shock
shock and/or
and/or
and/or
and/or damage
damage
damage
damage to
to
to
to the
the
the
the
instrument,
instrument,
instrument,
instrument, disconnect
disconnect
disconnect
disconnect circuit
circuit
circuit
circuit power
power
power
power and
and
and
and
discharge
discharge
discharge
discharge all
all
all
all high-voltage
high-voltage
high-voltage
high-voltage capacitors
capacitors
capacitors
capacitors before
before
before
before
measuring
measuring
measuring
measuring capacitance.
capacitance.
capacitance.
capacitance. Use
Use
Use
Use the
the
the
the dc
dc
dc
dc voltage
voltage
voltage
voltage
function
function
function
function to
to
to
to confirm
confirm
confirm
confirm that
that
that
that the
the
the
the capacitor
capacitor
capacitor
capacitor is
is
is
is
discharged.
discharged.
discharged.
discharged.
Capacitance is the ability of a component to store an
electrical charge.
17
The unit of capacitance is the farad (F). Most capacitors are
in the nanofarad to microfarad range. The Meter measures
capacitance by charging the capacitor with a known current
for a known period of time, measuring the resulting voltage,
then calculating the capacitance. The measurement takes
about 1 second per range.
The Meter's capacitance ranges are 4.000nF 40.00nF,
400.0nF, 4.000 µ
F,
40.00 µ F and 200.0 µ
F.
To
measure capacitance:
1. Set the rotary switch to Cap
Cap
Cap
Cap range.
2. Connect the black and red test leads to the COM
COM
COM
COM and Cx
Cx
Cx
Cx
terminals respectively.
3. Connect the test leads to the capacitor being measured
and read the displayed value.
Some
Some
Some
Some tips
tips
tips
tips for
for
for
for measuring
measuring
measuring
measuring capacitance:
capacitance:
capacitance:
capacitance:
¥ The meter may take a few seconds (200 µ F range, 30
seconds) to stabilize reading. This is normal for high
capacitance measuring.
¥
To
improve the accuracy of measurements less than 4nF,
subtract the residual capacitance of the Meter and leads.
3.2.6
3.2.6
3.2.6
3.2.6 Frequency
Frequency
Frequency
Frequency measurement
measurement
measurement
measurement
Do
Do
Do
Do not
not
not
not measure
measure
measure
measure Frequency
Frequency
Frequency
Frequency on
on
on
on high
high
high
high voltage
voltage
voltage
voltage
(>250V)
(>250V)
(>250V)
(>250V) to
to
to
to avoid
avoid
avoid
avoid electrical
electrical
electrical
electrical shock
shock
shock
shock hazard
hazard
hazard
hazard and/or
and/or
and/or
and/or
damage
damage
damage
damage to
to
to
to the
the
the
the instrument.
instrument.
instrument.
instrument.
1. Set the rotary switch to Hz
Hz
Hz
Hz range.
2. Connect the black and red test leads to the COM and Hz
terminals respectively.
3. Connect the test leads across the source or load under
measurement, and read the displayed value.
Note:
Note:
Note:
Note:
¥ In noisy environment, it is preferable to use shield cable for
measuring small signal.
18