1
Master Forge & M Design
®
is a
registered trademark of LF, LLC.
All rights reserved.
lowes.com/masterforge
®
ATTACH YOUR RECEIPT HERE
Serial Number _________________________ Purchase Date _________________________
Questions, problems, missing parts? Before returning to your retailer, call our
customer service department at 1-800-963-0211, 8 a.m. - 6 p.m., EST,
Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
ITEM #0503215
4-BURNER GAS GRILL
WITH SIDE BURNER
MODEL #1010048
AB13574
WARNING
Improper installation,
adjustment, alteration, service
or maintenance can cause
injury or property damage.
Read this instruction manual
thoroughly before installing or
servicing this equipment.
WARNING
1. Do not store or use gasoline
or 
and liquids in the vicinity of
this or any other appliance.
2. An LP tank not connected for
use should not be stored
in the vicinity of this or any
other appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.

3. Open the lid.
4. If the odor continues, keep
away from the appliance and
immediately call your gas

WARNING
For Outdoor Use Only
Español p. 36

Questions and Answers

  • F
    fbullockAug 15, 2025
    Why Master Forge 1010048 Grill or side cooker will not light?
    • J
      Julie HarmonAug 15, 2025
      If your Master Forge Grill or side cooker won't light, there are several potential causes. First, check if the ignition wire has come off the electrical igniter/valve and reconnect it. Also, make sure the distance between the ignition pin and the burner is within 5/32 in.-3/16 in. (side burner); adjust it if necessary. Other possible issues include a broken ignition wire (call customer service for a replacement), a dead battery (install a new AA battery), incorrect battery polarity (change the battery polarity), the electrode tip not producing sparks (reinstall the electrode), no gas supply (turn on the regulator valve), or an air shutter opening that is too big (adjust the opening to a smaller size).
  • K
    kunderwoodAug 18, 2025
    How to fix Master Forge 1010048 that will not light?
    • L
      Lawrence EvansAug 18, 2025
      If your Master Forge Grill or side cooker won't light, several factors could be at play. First, ensure the ignition wire is securely connected to the electrical igniter/valve. If it's detached, reconnect it. Next, check the distance between the ignition pin and the burner; it should be between 5/32 in. and 3/16 in. for the side burner. Adjust the pin if necessary. Also, try replacing the AA battery, ensuring it's correctly polarized. If the electrode tip isn't sparking, reinstall it. Make sure the regulator valve is on to supply gas. Additionally, verify that the air shutter opening isn't too large; if it is, reduce its size. If the ignition wire is broken, you'll need to call customer service for a replacement.
  • T
    Troy MillerAug 21, 2025
    What to do if Master Forge 1010048 has low heat on high?
    • P
      Paula LambAug 21, 2025
      If you're experiencing low heat on your Master Forge Grill even when the knob is in the 'HIGH' position, it might be due to blocked ports. Clear any obstructions from the ports. Alternatively, the LP tank might be empty.
  • T
    Timothy WilliamsAug 25, 2025
    Why is my Master Forge 1010048 low heat LP gas?
    • C
      Carol CherryAug 26, 2025
      If you have low heat with your Master Forge LP gas grill, it might be due to the propane regulator assembly. To resolve this: 1. Ensure all burners are off. 2. Open the tank valve and wait 5 minutes. 3. Light the burners one at a time, following the lighting instructions.
  • L
    Lori HunterAug 27, 2025
    What to do if burner blows out on Master Forge 1010048?
    • D
      Debra CoxAug 27, 2025
      If the burner on your Master Forge Grill blows out, there could be a few reasons. The LP tank might be empty. Also, the burner might not be correctly aligned with the control valve; ensure it is properly installed. Check the gas supply hose for leaks or knots.
  • A
    Andrew BauerAug 30, 2025
    What to do if the Master Forge Grill burner blows out?
    • R
      Ryan KingAug 30, 2025
      If your Master Forge Grill burner blows out, it could be due to several reasons. First, check if the LP tank is empty and refill it if necessary. Another potential cause is that the burner isn't correctly aligned with the control valve; ensure it's properly installed. Lastly, insufficient gas supply can cause this issue, so inspect the gas supply hose for leaks or knots.
  • C
    Chad HallSep 2, 2025
    How to prevent excessive flare-up on Master Forge 1010048 Grill?
    • M
      Misty WhiteSep 2, 2025
      Excessive flare-ups on your Master Forge Grill can occur for several reasons. If you're grilling fatty meats, do so when the grids are cold and the knobs are on the “LOW” setting, and move the meats to the warming rack if flare-ups continue. Ensure the knobs are turned to the “OFF” position before grilling. Never spray water on gas flames. Keep the hood up when grilling.
  • N
    Nicole JohnsonSep 6, 2025
    What to do if Master Forge 1010048 Grill has low heat with the knob in “HIGH” position?
    • K
      Kyle HenrySep 6, 2025
      If your Master Forge Grill is producing low heat even when the knob is in the “HIGH” position, it could be due to blocked ports. Clear any obstructions from the ports. Another possible reason is that the LP tank has run out; if so, refill the LP tank.
  • R
    Richard LoweSep 9, 2025
    Why Master Forge 1010048 burner flame is yellow and gas odor can be smelled?
    • B
      Brianna RodriguezSep 9, 2025
      If the burner flame on your Master Forge Grill is yellow and you smell gas, it could be due to spiders or insects blocking the air shutter. Clean any blockages and check for the source of gas leaks.
  • B
    Bryan RodriguezSep 12, 2025
    Why Master Forge 1010048 Grill yellow and gas odor can be smelled?
    • P
      Phillip McdowellSep 12, 2025
      If you smell gas and notice a yellow flame with your Master Forge Grill, it's possible that spiders or insects are blocking the air shutter. Clean any blockages and check for gas leaks.

Summary

Safety Information

Assembly Instructions

Assemble the grill hood

Steps to attach the hood and related components securely.

Assemble the left cart side

Connecting left cart legs to the side brace using screws.

Assemble the right cart side

Connecting right cart legs to the side brace using screws.

Assemble the wheels

Attaching wheels to the grill cart using axle and cotter pin.

Assemble the front cart panel bottom

Attaching the bottom front panel to the cart assemblies.

Assemble the front cart panel top

Attaching the top front panel to the cart assemblies.

Assemble the cart back brace

Securing the back brace to the cart side assemblies.

Assemble the grill and cart

Lifting and securing the main grill head onto the cart.

Installation Instructions

For Portable LP-Gas Connection

Connecting the grill to a portable propane gas tank.

Locating the Grill

Guidelines for safe placement and clearances around the grill.

Operating Instructions

Grill Lighting Instructions

Step-by-step guide for lighting the main and side burners.

Checking Gas Leaks

Method for detecting gas leaks using a soapy water solution.

Care and Maintenance

LP Gas Safety Requirements

Regulations and specifications for LP gas tanks and connections.

Troubleshooting

Master Forge 1010048 Specifications

General IconGeneral
BrandMaster Forge
Model1010048
CategoryGrill
LanguageEnglish