12
Problem: Loss of Water Pressure
Possible Cause
Solution
Fouled media bed due to iron.
Clean control valve and mineral bed
with cleaner.
Slots in riser pipe or laterals are
filled with media fines.
Inspect and clean distributor pipe slots
as needed.
Insufficient well pump
Check well pump gpm (gallons per
minute)
Problem: Timer does not display time of day
Possible Cause
Solution
AC Adapter unplugged
Connect power
No electric power at outlet
Repair outlet or use working outlet
Defective AC Adapter
Replace AC Adapter
Defective Timer
Replace Timer
Problem: Timer does not display correct time of day
Possible Cause
Solution
Switched outlet
Use uninterrupted outlet
Power Outage
Reset time of day
Defective Timer
Replace Timer
Problem: Control Valve regenerates at wrong time of day
Possible Cause
Solution
Power Outages
Reset control valve to correct time of
day
Time of day not set correctly
Reset to correct time of day
Time of regeneration incorrect
Reset regeneration time to 2:00 am.