Troubleshooting
Problem: Rotten egg odor returns
Add 1 qt. of chlorox bleach and
manually regenerate unit
Problem: Water conditioner fails to regenerate. No treated water.
Verify that electrical power is getting to
the outlet
Verify a minimum 30 psi inlet water
pressure
Insure that the drain line is free of
blockage
Manual bypass valve is open.
Close manual bypass valve.
Insure that riser pipe is properly sealed
at o’ring seal. Inspect pipe for cracks.
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Incorrect P Value Programming
Reprogram with proper P Value—
See Insert Sheet.
Problem: No Chlorine Draw
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Insufficient water pressure.
Verify a minimum 30 psi inlet water
pressure