INSTRUCTIONS MANUAL
-27-
A four-digit password can be entered to block the machine use. Once the password is entered,
it is possible to proceed from the main menu only after entering the code.
Entering 0000 as a password, the block is eliminated.
COUNTERS
This is used to check total COUNTERS of:: recovered gas, service alarm meter, total vacuum
minutes, injected gas, gas recovered into the bottle with the bottle refilling function.
From the SERVICES MENU:
Select COUNTERS and the following screen is displayed:
Use ↓ to scroll the lines.
This screen displays the total values for: gas recovered, service alarm COUNTERS, total
vacuum time (minutes), gas injected, gas recovered in the internal bottle using the “Bottle
filling” function.
Pressing START, COUNTERS can be printed out with date and time.
Rec. gas 0.0 kg
Service 0.0Kg
Vacuum 0 min
Syst. Fill. 0.0 kg
Bott. fill. 0.0 Kg
REFRIGERATION MANAGEMENT
PASSWORD
COUNTERS
. . . .