MAINTENANCE
42
MIG 180 INVERTER WELDER 058-9306-4
Maintenance
The welder needs regular maintenance as following:
Clean the dust, dirt, and grease periodically from the welder.
Every six months, remove the front panel from the welder to clear the accumulated dust and
dirt.
Replace power cord, ground cable, ground clamp or electrode assembly when damaged or
worn.
Repairs must be performed by a qualified service technician only.
Storage
Store the welder in a clean and dry location away from corrosive gas and excess dust at a
temperature of -12°C-48°C (10°F-120°F) and relative humidity of less than 90%.
It is recommended to repack the welder when transporting or storing the welder after use.
Cleaning is required before storage.
WARNING!
Potential hazard that could result in serious injury or loss of life.
Unplug the welder before performing any maintenance or service.
Only use the welder after replacing or repairing any damaged parts or
accessories.
Use only recommended and properly rated replacement parts. Failure to
comply could lead to serious injury or loss of life.
MAINTENANCE
REQUIRED
DESCRIPTION
MAXIMUM SERVICE INTERVAL
Monthly As Needed
In-depth inspection Worn or broken parts X X
Repair or replacement Worn or broken parts X