Page 21
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
PROBLEM POSSIBLE CAUSE SOLUTION
The wet/dry vacuum will
not operate.
1) No power supply.
1) Check the power supply, cord,
breakers, and fuses.
2) Faulty power cord.
2) Unplug and check the power cord.
If damaged, have it repaired by a
professional.
3) Collection tank is full. 3) Empty the collection tank.
4) Switch in the wrong position.
4) Press the ON ‘I’ button on the
power head.
The dust comes out from
the motor cover.
1) The cartridge filter is missing
or damaged.
1) Attach or replace cartridge filter.
2) Vacuum has been used to
collect fine dust, such as dry
wall dust, fireplace soot, or
ash, without a fine dust filter
equipped.
2) Remove the standard cartridge
filter and install the appropriate
fine dust filter.
Reduced efficiency and
motor/speed vibration.
1) There are blockages in
the nozzle or hose, or the
collection tank inlet.
1) Unplug and check nozzle, hose,
and collection tank inlets for
blockages.
2) The cartridge filter is clogged
by fine dust.
2) Take off the filter and clean it or
install a new cartridge filter.