16
MAC-PLUS
Always on
(Remote switch input
not used)
When the battery
charger must be
always active
Remote switch input
‘active low’
Enable the battery
charger by external
operating signal
Remote switch input
‘active high’
Enable the battery
charger by external
operating signal
Remote switch input
‘active low’
and
input voltage greater
than enable voltage
setpoint (12.50 V* /
25.00 V**)
Recommended
setting for vehicle
with proper engine
run signal
Remote switch input
‘active high’
and
input voltage greater
than enable voltage
setpoint (12.50 V* /
25.00 V**)
Recommended
setting for vehicle
with proper engine
run signal
Input voltage greater
than enable voltage
setpoint (13.50 V* /
27.00 V**)
(Remote switch input
not used)
Higher enable
voltage setpoint.
Setting for vehicle
without engine run
signal
Any other DIP switch combination
MasterBus settings
apply. See chapter
14 and 15.
* 12/12-50 and 12/24-30, **24/12-50 and 24/24-30