MAC-PLUS
17
Battery*
MasterBus settings apply.
See chapter 14 and 15.
Default factory setting: Flooded battery
Flooded battery
Bulk/Abs/Float: 14.25/14.25/13.25 V**
28.50/28.50/26.50 V***
Gel
Bulk/Abs/Float: 14.25/14.25/13.80 V**
28.50/28.50/27.60 V***
AGM
Bulk/Abs/Float: 14.25/14.25/13.80 V**
28.50/28.50/27.60 V***
Spiral
Bulk/Abs/Float: 14.25/14.25/13.80 V**
28.50/28.50/27.60 V***
Traction
Bulk/Abs/Float: 14.55/14.55/13.25 V**
29.10/29.10/26.50 V***
NiCad
Bulk/Abs/Float: 14.50/14.50/14.50 V**
29.00/29.00/29.00 V***
Constant output voltage 13,25 V*/26,50 V***
* For Li-Ion see MasterBus settings, chapter 14 and 15
** 12/12-50 and 24/12-50
***12/24-30 and 24/24-30