EasyManua.ls Logo

Mastervolt Mac Plus 2/12-50 - Page 31

Mastervolt Mac Plus 2/12-50
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAC-PLUS
31
Value
Meaning
Factory setting
Adjustable range
Remote sw. input
Mode
Acitve low: active if voltage
between 0-0.5 V, Active high:
active if voltage between 3-32
V, Not used: always active
Active high
Not used, Active
low, Active high
Input threshold
Enabled
Enabled: input voltage
thresholds are active
Disabled: input voltage
thresholds are not active
Enabled Enabled, Disabled
Enable voltage Enable input voltage 12.50 / 25.00 V 8-16 / 16-32 V
Enable delay
Enable delay
2 s
0-300 s
Disable voltage Disable input voltage 12.00 / 24.00 V 8-16 / 16-32 V
Disable delay
Disable delay
300 s
0-300 s
Instant disable
Disable input voltage, no
delay
11.00 V 8-16 / 16-32 V
Sleep delay
Delay before the Mac Plus
switches to sleepmode
300 s 0-3600 s
Charger
Battery type
Selection of pre-set charge
algorithm. Individual
adjustments are only possible
if “User defined” is selected
here.
Flooded
Flooded, Gel,
AGM, Spiral, Li-
Ion, Traction,
NiCad, Constant
voltage, User
defined,
Max output
Maximum output (charge)
current
50 A
30 A
0-50 A
0-30 A
Max input Maximum input current
50 A
30 A
0-50 A
0-30 A
Current ramp up
Charge current ramp up after
enabling the charger.
5 A/s 0-50 A/s
Temp. compensate
Temperature compensation
for charge voltage
-0.030 V/°C
-0.060 V/°C
-0.1 - +0.1 V
Value
Meaning
Factory setting
Adjustable range
Shunt
Shunt device
(available in upcoming
software update)
Selection of the shunt device to
which the Mac Plus is
connected. This can either be a
No connection
No connection,
MSH+Product