MasterShunt (MSH) or a MLI-
Ultra battery (BAT). Enabling
this function allows
to: - Compensate the charge
voltage for cable losses - Adjust
the actual Charge state based
on the state of charge of the
battery - Compensate the
charge voltage for deviating
battery temperatures
(MasterShunt only)
Max. bulk time Maximum bulk time 480 min 0-1440 min
Start bulk time Start bulk timer 13.25 V 8-15 / 16-30 V
Bulk return time Return to bulk time delay 30 s 0-240 s
Abs. voltage Absorption voltage 14.25 / 28.50 V 8-15 / 16-30 V
Min absorp. time Minimum absorption time 15 min 0-240 min
Return amps
Return amps (% of maximum
charge current)
6 % 0-50 %
Float
Constant voltage
Constant voltage Constant output voltage 13.25 / 26.50 V 8-15 / 16-30 V
Input alarm
High input voltage alarm on
High input voltage alarm off
Low input voltage alarm off
Low input voltage alarm on
Low input alarm delay time