MasterShunt 500 – User and Installation manual
8 Specifications
8.1 Technical specifications
MasterShunt 500 (MasterBus)
Gel, AGM, flooded, Lithium Ion
0-10A: <0.2A resolution, 10-100A: <0.5A resolution, 100-600A: <5A resolution
± 0.8 % of reading ± 1 digit
Maximum current (With busbar or T-
fuse 500A)
300A continuously
400A for 10 min.
500A for 5 min.
600A for 2 min.
Yes, for load currents which exceed 300A continuously
30-10000 Ah (5 Ah resolution)
0-480 hours (1 min resolution)
Maximum number of configurable
events
English, Nederlands, Deutsch, Francais,
Castellano, Italiano, Norsk, Svenska,
Suomi, Dansk.
See related display settings
bus bar included in MasterShunt, Class T fuse or ANL fuse to be ordered separately
23 mA (normal operation), <1 mA (power saving, MasterBus off)
e.g. time remaining, voltage, current, state of charge
warning low voltage, low state of charge, high voltage
150 x 150 x 65 mm
5.9 x 5.9 x 2.6 inch