Display Type | LCD |
---|---|
Current Measurement | Yes |
Weight | 0.3 kg |
Operating Temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
Protection class | IP21 |
Protection Degree | IP21 |
Battery Banks | 1 |
Measurement range temperature | -20 to +50 °C |
Accuracy current | ±1% |
Accuracy temperature | ±1°C |
Storage temperature | -30°C to +70°C |
Current Measurement Range | 0-999A |
Measurement range current | 0-999A |
Accuracy voltage | +/- 0.5 % |
Covers usage manual, guarantees, quality, validity, liability, and changes to the Masterlink BTM III.
Details warnings, intended use, organizational measures, maintenance, repair, and battery safety.
Introduces monitoring, features, and software for the Masterlink BTM-III battery monitor.
Explains the LCD display, LED bar, Set/Select buttons, alarm function, and submenus.
Lists required tools and materials, and provides step-by-step installation guidance for the device.
Guides through language setting and synchronization for initial setup and calibration.
Describes the initial level, consumed amp-hours, and short/long menu views of battery status.
Explains how to access and navigate through the device's various submenus for settings.
Covers time since start-up, low battery alarm, full charge, cycles count, and abuse cycles.
Details discharged time, calculated CEF, total consumed amps, and average discharge.
Shows deepest discharge, highest voltage for all battery banks, and exit level.
Covers battery naming, nominal voltage, and capacity settings for each bank.
Details charger current, average amps, alarm functions, and voltage setpoints.
Explains state of charge levels, minimum/maximum runtime alarms, and exit.
Covers lock mode, language, energy save mode, and Charge Efficiency Factor for battery bank 1.
Details Peukert exponent, historical data reset, charge amps, and float voltage for bank 1.
Includes settings for Shunt, CEF, Peukert exponent, data reset for banks 2 & 3, and SOC visualization.
Covers factory reset, software version, NMEA output, and exit level settings.
Explains battery alarm functions and the Charge Efficiency Factor (CEF).
Details Peukert exponent calculation, state of charge methodology, and battery replacement.
Describes MasterAdjust software for configuration and the Peukert Calculator tool.
Lists available battery names, NMEA0183 format, and ordering information for parts.
Provides a table of common failures, possible causes, and recommended solutions.
Lists detailed technical specifications, including voltage, current, accuracy, and languages.
Provides diagrams and measurements for the Masterlink BTM panel and its installation cover.
States the product conforms to EC EMC and safety directives and applied harmonised standards.