INSTALLATION
US / WHISPER 6/8/11 / July 2009 / Copyright © 2009 Mastervolt 19
2.2 COMMISSION TABLE
1 Check if a siphon breaker (air vent) is necessary and
has been installed
2 Open the seawater inlet valve and check all water
connections. Check if the strainer is installed above
the seawater level.
3 Check if the exhaust system is properly installed.
Check maximum length of exhaust hose, diameter of
exhaust hose, position of the waterlock, maximum lift.
Also check the minimum required height of 24” (60
cm) above sea level of the exhaust loop (goose neck).
4 Open the seawater outlet valve and check all water
connections.
5 Check the AC cables and the grounding.
6 Check if an AC breaker is installed before or after the
power source selector. When there is only a circuit
breaker, use it to disconnect the generating set from
the grid.
7 Check all DC connections, check if the battery switch/
circuit breaker is closed.
8 Open the fuel valve and bleed the fuel system. Check
if there are no air leaks in the fuel supply line, and
check if the lift of the fuel is less than 3 ft (1 meter).
Check if there is no air in the water fuel separator.
9 Check if the air intake in the canopy is not blocked.
10 Check the oil level and color of the oil. Check the
coolant level
11 To bleed the fuel system push the startbutton on the
local control (not on the remote panel) and hold at
least 5 seconds and as long as necessary to bleed
the system.
12 Start the engine by pushing the start button.
13 Check when the generating set is running, the delay
of 5 to 10 seconds in the power source selector
transfer.
14 Check voltage and frequency under ‘no load’
conditions.
15 Check voltage and frequency under ‘full load’
conditions.
16 Check if the battery charger of the generating set is
working (max. 14.5 Volt).
17 Close the sound shield and check the noise level.
18 Stop the generating set and check the engine again
for leakages of oil, fuel or water.