The AC442 must always be transported in its operating
position. Never lay the AC442 on its side, as oil could
then escape from the vacuum pump or the built in
compres
sor could be damaged.
There are no additional
safety systems for protecting the
AC442 against
damage resulting from natural catastrophes.
We recommend calibrating the scales at least once per
year.
Contact customer service for calibration of the scales.
The AC442 must be subjected to regular maintenance by
service personnel or authorized agents to ensure the safety
of the unit.
Disconnect power before performing any maintenance
or
service to unit.
Never perform any maintenance work which is not
expressly
recommended in this manual. Contact
customer service if
components have to be replaced
other than in the course of
maintenance work.
The AC442 must be connected to a properly grounded
electrical connection.
If there is damage to the AC442, terminate usage
imme
diately and contact customer service.
The service hoses and service quick-release couplings must
be regularly checked for wear and replaced if damaged.
The AC442 must be operated in an environment
corresponding to the directive BGR 157 with respect to
the
exchange of air.
Observe local laws or directives as to ensure the safety of the
pressurized device.
Follow the pertinent legal regulations or directives to
ensure
safe handling of pressurized devices.
For safety reasons it is advisable to use a residual current
operated circuit breaker (rccb) with the following
specifications:
Parameters
Rated voltage
110 VAC ± 10%
Rated frequency
50/60Hz
Rated current
10A
Rated tripping current 30mA
Tripping switch
C
Never remove any components from inside the AC442
except for maintenance or repair purposes.
Avoid using an extension cord with the unit. If
necessary, use a good condition (three wire grounded,
#14AWG or larger) extension cord of the shortest
possible length. In addition, the current drawn by all
devices connected to the wall socket must not exceed
15A total.