EasyManua.ls Logo

Matco Tools AC442 User Manual

Matco Tools AC442
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TSL-50
|
1
Foreword
1901016-85
EN
Operation Manual
A/C Service Equipment
AC442
R134a TOUCHSCREEN AUTOMATIC RRR
Question and Answer IconNeed help?

Do you have a question about the Matco Tools AC442 and is the answer not in the manual?

Matco Tools AC442 Specifications

General IconGeneral
ModelAC442
CategoryTest Equipment
TypeA/C Manifold Gauge Set
Hose Length60 inches
High Side Gauge Range0 to 500 PSI
Gauge Size3-1/8 inches
MaterialBrass

Summary

Symbols Use and Important Notes

Documentation Symbols and Warnings

Explains warning notice structure, symbols in documentation, and on-product warnings.

User Group and Agreement

Defines intended users and outlines copyright and software usage terms.

Contractor Obligations and Safety Rules

Contractor's Obligation and Basic Rules

Details contractor duties for safety, accident prevention, and equipment setup.

Mandatory Electrical Tests

Outlines required electrical system testing procedures and record-keeping.

Safety Regulations for AC442

AC442 Specific Safety Precautions

Lists critical safety rules for operating the AC442 unit and handling refrigerants.

Operational, Maintenance, and Electrical Safety

Covers safe operation, maintenance, transport, and electrical connection guidelines.

Technical Data, Disposal, and Glossary

Safety Devices and Disposal Guidelines

Explains safety device functions and responsible disposal of equipment.

Packaging, Filter Disposal, and Technical Specifications

Covers packaging disposal, filter disposal, unit specifications, and definitions.

Product Description

Application and Scope of Delivery

Details the AC442's applications and lists all included items.

Unit Description and Views

Front, Rear, and Connection Views

Identifies key components in various views of the AC442 unit.

Internal Component Identification

Identifies major internal parts of the AC442 unit.

Input Selection and User Interface

Selection Keys and Touchscreen Operation

Explains how to navigate and select functions using the touch display and keys.

Display Screen and Status Indicators

Describes the main screen elements, including gauges and indicator lights.

Main Menu Navigation

Lists the primary functions accessible from the main menu.

Key Unit Features and Couplers

Details features like EcoLOCK couplers, caster brakes, and power connections.

Functional Description of Components

Explains the operational purpose of key components like the vacuum pump and purging unit.

Equipment Installation

Safe Unpacking of the AC442 Unit

Provides instructions for safely removing the AC442 from its packaging.

Commissioning and Initial Setup

Connections, Positioning, and Power

Guides on setting up the unit, connecting power, and ensuring proper placement.

First Start-Up Verification Procedure

Outlines the initial checks and procedures for the first operation of the AC442.

System Setup and Parameter Configuration

Explains how to configure various parameters via the SETUP menu.

Internal Refrigerant Cylinder Filling

Details the process for filling the unit's internal refrigerant cylinder.

A/C Service Preparation

Preliminary Preparation and Safety

Covers essential preparatory work before performing vehicle A/C service.

Non-condensable Gas Discharge

Explains the process of purging non-condensable gases from the system.

Understanding Refrigerant Charge Modes

Describes the Quick Mode and Zero Tolerance Mode for refrigerant charging.

A/C System Service Operations

Setting Up Automatic A/C Cycles

Guides on configuring and performing automatic A/C service cycles.

Setting Up Manual A/C Cycles

Details how to set up and perform A/C service using manual cycles.

Refrigerant Recovery Process

Explains the steps for recovering refrigerant from a vehicle's A/C system.

Vacuum Process and Time Adjustment

Details the procedure for creating a vacuum and adjusting vacuum time.

Refrigerant and Oil Charging

Outlines the steps for charging the A/C system with refrigerant and oil.

System Flushing and Pressure Checks

Covers flushing procedures and testing vehicle A/C system pressures.

Unit Configuration: Units, Clock, and Language

Guides on setting units of measure, clock, and language preferences.

Maintenance Procedures

Maintenance Intervals and Cylinder Filling

Lists recommended maintenance intervals and how to fill the internal refrigerant cylinder.

Self-Test, Pressure Zero, and Counters

Explains self-tests, pressure zero setting, and viewing maintenance counters.

Long Life Pump Test Operation

Details the procedure for performing the long-life pump test.

Vacuum Pump Oil Change Procedure

Provides instructions for changing the vacuum pump oil and resetting the counter.

Filter Dryer Replacement Process

Details the process for replacing the filter dryer and entering its code.

Printer Maintenance and Periodic Checks

Covers optional printer maintenance and essential periodic operational checks.

Spare Parts List

Available Replacement Components

Lists available spare parts for the AC442 unit with their order numbers.

Maintenance Log Records

Vacuum Pump Oil Change Log

Provides a log for recording vacuum pump oil changes.

Filter Dryer Change Log

Provides a log for recording filter dryer replacements.

Refrigerant Load Cell Calibration Log

Provides a log for recording refrigerant load cell calibration checks.

Other Maintenance and Repair Log

Provides a log for recording various maintenance tasks and repairs.

Notes and Remarks Section

Provides space for general notes and remarks related to maintenance.

Related product manuals