8.6 TROUBLESHOOTING - ERROR 04B0
CHAPTER 8: TROUBLESHOOTING
FIGURE A FIGURE B
ERROR CODE 04B0
1) SYMPTOM:
04B0 – LCB communication disconnected.
2) SOLUTION:
1) Check the connection of the console cable at the UCB and LCB. Also check the console cable for damage, replace as needed.
2) If the console cable connections are good, the issue is likely with the UCB. Replace the console.
3) If the console does not resolve the issue, replace the LCB.