27
8) Fitting of the command console
The command console must be ! tted to the structure by inserting the prop into the welded support on the structure
in order to make the holes for the ! xing pivot match; the ! xing pin allows the console to rotate making checking
and maintenance easier to carry out; in this ! rst stage much attention must be paid to the feeding through of
the connection leads and to the electronic circuit which must be inserted beside the latch which is situated on
the inner side of the support arm, ! xing them with the central tabs. There is a mechanical safety release device
on the clamp of the console which is on the back of the prop; a nylon washer which must be rotated over the
welded support in order to ensure the ! tting of the console in the correct position for use.
9) Fitting of turbines for regulated ventilation at foot end
Place the accessory containing the turbines for regulated ventilation at the foot end on the four pivots situated
on the upper ring and tighten the grub screws in order to ! x the accessory to the structure.
NB: Before ! xing check the electrical connection.
10) Fitting of Plexiglas tubes for body ventilation
Insert the Plexiglas tube on the foot end, paying attention that the OR, which is a packing, has been just inserted,
then pull the tube towards the head end, make sure that the OR has been positioned correctly, so as to be able to
screw the dowel in its place on the Plexiglas tube (the dowel must be screw form the inner side of the support
ring). The same procedure is followed for both tubes.
11) Fitting of the Plexiglas
The Plexiglas must be ! tted onto the carrying frame which will in turn be placed on the 4 support pivots. The
angled grooves on the 4 points of support of the structure assure perfect anchorage to the structure.
To remove, it is suf! cient to lift the Plexiglas slightly at the front then slide it off the back support pivots; to
make cleaning and maintenance of the lower solar groups easier the Plexiglas top has two rods, which are ! tted
to the two side supports, which will hold it up if it must remain open.
12) Filter cleaning and lamp changing
Access to the internal prts such as ! lters and lamps is very easy; the Plexiglas door snaps shut so it is suf! cient
to pull on it on the side where it is free of hinges in order to open it, after which it is suf! cient to turn the screws
that ! x the door of the Blue ! lters to access to temperated ! lters and after to the lamps, at this point it is possible
to carry out cleaning, maintenance and changing of the lamps.
NB: During maintenance and cleaning it is very important not to move the ! lters from their ! ttings as this
risks setting off the control alarm for broken ! lters, also the slightest movement may cause the interruption of
the control circuit.
ONLY FOR INFORMATION
www.isoitalia.us