T3x Error Codes LCD Console Board W / MEEEX LCB 
12
 E6 – Elevation Range / Elevation Stall 
 
OVERVIEW 
When elevation movement is commanded (e.g. elevation up) the elevation position feedback is expected to change in the correct 
direction (e.g. increase in pot value for an elevation up command).  If the elevation position feedback changes in the opposite of the 
expected direction (e.g. elevation command up and elevation feedback decreases) a reverse elevation error (E3) is flagged. 
To prevent the elevation from stalling at the lower travel end or running off on the top end of travel the elevation position feedback is 
monitored.  If the elevation position feedback is lower than expected (e.g. < 10) or higher than expected (e.g. > 250) then an (E3) is 
called.   To reduce the risk of elevation motor/system damage or overheating in the event of a stall elevation stall conditions are 
monitored.  If movement is commanded and the position feedback indicates no movement-taking place an elevation stall error is 
called.   This problem has been caused most frequently by overheated elevation motor. 
. 
Solution Flow Chart