T3x Error Codes LCD Console Board W / MEEEX LCB
5
E1 - Speed Feedback Error
OVERVIEW
If no belt movement is detected 10 seconds after pressing START the console calls a speed stall error (E1).
During normal run time operation the value stored during auto calibration is used to initially set the speed (e.g. target speed = 12
MPH, PWM ticks = Maximum PWM = 999). Once the speed is stabilized the actual speed is monitored and if different than the
target speed the PWM value is adjusted until the actual speed matches the target speed. If the PWM value is changed by more
than the amount of ticks required to change .8 MPH and the actual speed does not match the target speed then an (E1) error is
flagged. This error indicates the motor controller system is unable to maintain the target speed.