EasyManua.ls Logo

Mattei BLADE 4 - Advanced Troubleshooting; Oil, Temperature, and Noise Issues

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.02
TI013G0008
PROBLEM CAUSE SOLUTION
C. Oil
Excessive oil consumption;
the level lowers too quickly; oil
is detected within the network.
The air-oil separator lter is
clogged.
Replace the lter.
(See chapter 7)
D. Temperature
The compressor stops due to
its own over-heating.
The radiator or the lter of
the cooling air is dirty; the
environmental temperature is
excessive for the compressor
operation.
Verify the cause and remove
the problem.
(See chapter 7)
The compressor stops due to
the over-heating of the motor.
Excessive working pressure. Verify the setting and re-set to
the design value for the machi-
ne.
(See chapter 7)
The main motor cooling is
insuf cient; the cooling air is
either too hot or too little.
Verify the environmental con-
ditions and the condition of the
ltering panel.
(See chapter 3 and 7)
E. NOISE LEVEL
Belts are noisy.
Belts are not tightened enou-
gh.
Correcly tighten the belts.
(see chapter 7).
Troubleshooting

Table of Contents

Related product manuals