b.
Remove canister end cap to gain access to element.
IMPORTANT: When safety element is dirty, it should be replaced. Do not attempt to clean.
Battery
CAUTION: BATTERY ELECTROLYTE IS A CAUSTIC ACID. KEEP IT AWAY FROM
SKIN AND EYES. IF CONTACT OCCURS, FLUSH THE AFFECTED AREA
WITH LOTS OF WATER.
CAUTION: DISCONNECT GROUND CABLE FROM THE NEGATIVE BATTERY POST
BEFORE ATTEMPTING TO SERVICE OR REMOVE BATTERY.
1.
Removal
a.
Disconnect ground (negative) cable from battery (-) terminal.
b.
Remove the battery retainer bracket.
c.
Disconnect positive cable from battery (+) terminal.
2.
Cleaning
a.
Remove battery, following correct procedures.
b.
Thoroughly clean terminals with a battery-cleaning tool.
c.
Mix to paste solution of baking soda and water and apply to battery and
terminals.
d.
Rinse battery and machine area near battery liberally with water.
3.
Installation
a.
Clean battery, follow correct procedures.
b.
Be certain battery area is clean and clear of debris.
c.
Install battery and retainer bracket.
d.
Connect positive (+) cable to terminal.
CAUTION: DO NOT CONNECT NEGATIVE (GROUND) TERMINAL FIRST. ARCHING
CAN OCCUR, POSSIBLY CAUSING SEVERE BURNS AND / OR
BATTERY EXPLOSION.
e.
Connect negative (-) terminal.
4.
Charging
a.
Connect charger leads to proper battery terminals then precede according to
charger manufacturer’s instructions.