For detailed installation instructions and COMPLETE information about ALL the available options & features for
the MAX Megatron, please refer to the MAX Megatron Installation and Owners manual.
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
PhotoCell
Edge
UL Entrap
1
2
Limit SW
ON-LINE
MATRIX
JOG
LEFT
JOG
RIGHT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ERD
Motor
OverLoad
POWER
MC-200
Motor Controller
16
15
14
13
12
3
4
5
MAX
LED ON
Edge
Sensitivity
ERD
CLOSED
LIMIT
OPEN
LIMIT
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETYCENTEREXIT
OPEN
MAX
GATE SPEED
STOPCLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFFON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
CLOSING Photocell Beam can be 5” or less away from gate
CLOSED Gate
Receiver to MC-200 EDGE 1 Input
Transmitter
Concrete Pad
24”
12” 6”6”
30”
8”
8”
14”
24”
30”
Pivot
Point
Pivot
Point
Long Arm
Short Arm
10”
12”
12”
5.5”5.5”
8.5”
Conduit
Area
Concrete Pad
Operator Placement
A
A
B
C
Secure gate operator
to concrete pad with
six (6) 1/2” x 3” (min)
sleeve anchors.
1/2
MOTOR
Power In
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
MATRIX
BOARD
ALARM
BATTERY
PACK
LIMIT
SWITCH
MOTOR
INPUTS
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETYCENTEREXIT
OPEN
MAX
GATE SPEED
STOP CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFFON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ON/OFF
Battery
EF1/2
Battery Voltage
Replace
Battery
TEST
Battery
Battery IN
Error
MAX BC-7
Battery Module
Conduit
Ground Level
Check local building codes in
your area for depth of concrete
(2 ft typical).
6” Above
Ground
A should be at least 1/4 the gate length.
NOTE: Uphill or heavy gates - should be at least 1/3 the gate length.
B 15” minimum for open gate clearance (2” thick gate).
C distance “A” minus 17 inches (A - 17 = C).
Arm Restrictions
•
71” MAX length for arms.
• Long arm should be 90° from gate when OPEN.
• Arms should NOT be completely straight when CLOSED.
See
Arm Position on next page.
Calculations MUST be followed:
1
2
Photocell
Beam Height:
21” Normal
27.5” Max.
Models: 1400/2200/FAST = 19”
Models: 1400HP/2200HP = 27.5”
Models: 1400/2200/FAST = 25”
Models: 1400HP/2200HP = 33.5”
www.max.us.com
Quick Install Guide
for MAX Megatron
ONE Entrapment protection sensor
MUST installed or operator will NOT
function. It MUST be MONITORED
and NORMALLY CLOSED (N.C.).
UL 325 2016 Standard
1
UL 325 2016 Standard-Megatron Quick Install Rev 10