limit switch adjustment
7
F
US
E
7 Am
p
PO
WER
115V
AC
3A
ma
x
On
O
ff
WARNING
: For
co
nti
nued
p
r
o
te
ct
i
on
agai
n
st fir
e
,
r
e
pl
ace
on
l
y
wi
t
h
the
sa
me
typ
e
and
r
a
t
i
n
g of
f
use
.
A
V
E
RTIS
SEM
E
NT
:
p
our
ne
pa
s
co
mprome
t
tr
e
l
a
prot
e
c
t
i
o
n co
nt
r
e
l
es
r
i
sq
ues
d’
i
nc
e
ndie,
uti
l
i
se
r
un
fusibl
e
de
m
ê
mes typ
e
et
ca
ract
é
r
i
st
i
ques
nominal
es
.
ON/O
F
F
B
a
ttery
E
F
1/
2
Ba
t
tery Vo
l
t
ag
e
Re
p
l
ac
e
Battery
TE
S
T
Batte
r
y
B
attery
IN
Erro
r
MAX BC-
7
B
a
tte
r
y
Mo
d
ul
e
P
h
o
to
C
e
l
l
E
d
g
e
U
L
E
n
tr
a
p
1
2
L
i
m
i
t
S
W
ON-L
IN
E
MA
T
R
IX
JOG
LE
F
T
JOG
R
I
G
H
T
J
o
g
LT
J
og
RT
G
ND
Ed
ge
1
Ed
g
e
2
P
h
o
t
o
Cell
E
R
D
Mot
or
O
ver
Loa
d
P
O
WE
R
MC-2
0
0
M
ot
or
C
ont
r
ol
l
er
1
6
15
1
4
1
3
1
2
3
4
5
MA
X
L
E
D
O
N
E
d
g
e
S
e
n
s
i
ti
vi
ty
ER
D
MO
TO
R
Po
w
er In
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
M
A
TR
I
X
B
OA
RD
AL
A
R
M
B
AT
T
E
R
Y
P
A
C
K
LI
M
IT
S
WI
T
CH
M
O
TO
R
IN
PUTS
24
V
GN
D
UL
A
L
A
R
M 1
2
V
A
L
A
R
M R
ET
RE
SE
T
G
ND
G
AT
E
TAMPER
MA
G
L
OCK
OP
EN
RIGHT
O
P
E
N
L
EF
T
MA
G
LO
C
K
DE
L
A
Y
P
R
I
MA
RY
G
A
T
E
S
AF
E
TY
C
E
NT
ERE
X
I
T
O
PE
N
MA
X
G
AT
E
SP
E
E
D
STOP
C
L
O
S
E
AN
T
I
T
AI
L
GA
T
E
C
LOS
E
T
I
ME
R
P
O
SI
TI
ON
RE
COR
DE
R
I
D
P
L
U
G
AUTOMATI
C
OPE
N/CLOSE
CO
N
TR
O
LS
B
AT
T
E
RY
B
AC
K
-U
P MO
D
E
M
AT
R
I
X
1
P
HO
T
O
C
E
L
L
E
D
GE
1
E
D
GE
2
I
D
PL
U
G
ERROR
O
PE
N
C
OM
C
L
OS
E
T
a
mp
e
r
N
O
C
OM
G
ND
T
a
mp
er I
N
O
F
F
O
F
F
ON
E
XI
T
P
AR
TIA
L
O
PE
N
O
BD
P
O
RT
BLACK
BO
X
MOTOR
MO
TION
C
E
NT
ER
R
E
VE
RS
E
SE
NSI
T
I
VIT
Y
M
O
T
OR
O
V
E
R
L
O
A
D
N
O
L
I
M
I
T
SW
I
T
C
H
/
CL
A
M
P
SL
I
P
P
I
N
G
M
IN
M
A
X
1
2
V
D
C
GND
2
4
V
D
C
G
ND
M
A
X
MI
N
OF
F
S
A
F
E
T
Y
L
E
A
VE
O
P
EN
L
E
A
VE
C
L
O
S
E
D
M
A
D
E i
n
U
S
A
O
P
E
N
1
T
I
M
E
2
S
e
c
1
.
5
S
e
c
COM
N
C
B
AT
T
E
R
Y
I
N
US
E
P
OWE
R
G
AT
E
S
TAT
US
MO
TO
R
O
N
-
LI
N
E
LI
M
I
T
S
WI
TC
H
O
N
-LI
N
E
(
+)
G
ND
(
-)
PR
I
M
AR
Y
G
A
T
E
(
+)
G
ND
(
-)
SE
C
G
A
T
E
UL
E
NTR
A
P
PH
O
T
OCEL
L
GND
ST
R
IKE
G
N
D
KE
Y
PA
D
/
R
D
R
GND
FIR
E
DEP
T
G
N
D
MA
X
O
P
E
N
G
N
D
R
A
D
I
O SIG.
R
A
D
I
O G
N
D
OP
E
N
ST
OP
CL
O
S
E
CO
M
GA
T
E
D
ISABL
E
The limit rings need to be set BEFORE the gate can be cycled or DAMAGE could occur.
Push and HOLD the JOG LEFT or JOG RIGHT buttons
accordingly on the MAX MC-200 motor controller to
move the gate (release the button to stop gate).
Re-adjust limit ring postions as desired.
R
o
t
a
t
e
C
L
O
S
E
D
r
i
n
g
u
n
t
i
l
L
E
D
l
i
g
h
t
s
CLOSED
LIMIT
OPEN
LIMIT
Arm in
CLOSED position
Adjust Limit Switches:
CLOSED
LED
lights
Limit Ring
Screw has
NO GAP when
tightened.
Limit Ring
Screw has
NO GAP when
tightened.
1. Move gate to CLOSED position.
2. Loosen closed limit ring screw.
3. Rotate closed limit ring until closed LED lights.
4. TIGHTEN CLOSED limit ring screw
leaving NO gap.
5. Move gate to OPEN position.
6. Loosen open limit ring screw.
7. Rotate open limit ring until open LED lights.
8. TIGHTEN OPEN limit ring screw
leaving NO gap.
IMPORTANT: Manually Secure Arm
Make sure power is ON. Manually Release Arm.
“Fine Tune” Limit Rings Adjustment
IMPORTANT: LEDs MUST light up when gate reaches OPEN and CLOSE
positions or operator WILL NOT learn gate positions. If gate positions are
not learned, gate cycling speed will remain SLOW during normal operation.
IMPORTANT: Remove breather
pin from gear reducer BEFORE
cycling operator.
Breather Pin
CAUTI
ON
REMOVE
BEFORE
OPERATION
PhotoCell
Edge
UL Entrap
1
2
Limit SW
ON-LINE
MATRIX
JOG
RIGHT
JOG
LEFT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ERD
Motor
OverLoad
POWER
MC-200
Motor Controller
16
15
14
13
12
3
4
5
MAX
LED ON
Edge
Sensitivity
ERD
CAUTION
Make sure OPEN/CLOSE
limit rings are tightened
after adjustment or
slippage could occur.
R
o
t
a
t
e
O
P
E
N
r
i
n
g
u
n
t
i
l
L
E
D
l
i
g
h
t
s
CLOSED
LIMIT
OPEN
LIMIT
Arm in
OPEN position
OPEN
LED
lights
adju
st
bol
t
f
or firm
g
rip
Manual Release
Short Arm
Positive Stop
on Long Arm
1/4” gap
Arm in Closed
Position
IMPORTANT: DO NOT allow positive stop
on long arm to touch short arm in closed
position. Leave about a 1/4” gap.
6
UL 325 2016 Standard-Megatron Quick Install Rev 10