MANUALE UTENTE - INSTALLATORE PER CLIMATIZZATORE PORTATILE
IT
PORTABLE AIR CONDITIONER USER’S – INSTALLER’S MANUAL
EN
MODELLI / MODELS
N-P35A2, P35A2
Questo manuale è stato creato per scopo informativo. La ditta declina ogni responsabilità per i risultati di una progettazione o di una installazione
basata sulle spiegazioni e le specifiche tecniche riportate in questo manuale. E’ inoltre vietata la riproduzione anche parziale sotto qualsiasi forma
dei testi e delle figure contenute in questo manuale.
This manual has been created for informative purposes. The company declines any responsibility for the
results of projects or installations based on
the explanations and the technical specifications provided in this manual. It is besides forbidden the reproduction under any form of the texts and of
the figures contained in this manual.

Questions and Answers

  • A
    Ashley WongJul 30, 2025
    What to do if my MAXA N-P35A2 Air Conditioner does not start?
    • J
      Jason ByrdJul 30, 2025
      If your MAXA Air Conditioner doesn't start, check the following: * Ensure the power supply is properly connected. * Make sure the power plug is tightly inserted. * If the issue persists, the power plug or socket may be malfunctioning and need replacement. * Also, the fuse might be broken and require replacement by a maintenance professional.
  • L
    lisabyrdAug 3, 2025
    Why is my MAXA Air Conditioner not cooling enough?
    • M
      Michael JeffersonAug 3, 2025
      If your MAXA Air Conditioner isn't cooling enough, it could be due to a couple of reasons: * If the room temperature is lower than the set temperature, this is normal operation. * The evaporator might be frosting. In this case, the unit is in defrosting operation and will resume normal operation after defrosting is complete.
  • B
    Beth WigginsAug 8, 2025
    What does F1 error mean on MAXA Air Conditioner and how to fix it?
    • L
      Linda MoranAug 8, 2025
      The "F1" error on your MAXA Air Conditioner indicates a malfunction of the evaporator temperature sensor. Check if the indoor room temperature sensor is properly connected.
  • D
    danieldavidsonAug 11, 2025
    How do I troubleshoot F2 error on MAXA N-P35A2 Air Conditioner?
    • M
      Melissa KnightAug 11, 2025
      The "F2" error code on your MAXA Air Conditioner signals a malfunction of the evaporator temperature sensor. Check if the evaporator temperature sensor is properly connected.
  • D
    Donald HaydenAug 16, 2025
    How to fix H8 error on MAXA Air Conditioner?
    • M
      matthew01Aug 16, 2025
      The "H8" error code on your MAXA Air Conditioner indicates that the water tank is full. Empty the water tank to resolve this issue. If the error persists after emptying the tank, contact a maintenance professional.
  • K
    Kendra SolisAug 20, 2025
    What to do if MAXA N-P35A2 shows F4 error?
    • Z
      Zachary CoffeyAug 20, 2025
      If your MAXA Air Conditioner displays the "F4" error, it could be due to several reasons: * The wiring terminal between the outdoor condenser temperature sensor and the controller may be loose or poorly connected. Try removing the temperature sensor and re-inserting it to ensure it's stable. * There might be a short circuit due to tripped parts on the controller. Inspect the circuit on the controller. * The outdoor condenser temperature sensor could be damaged and need replacement. * The main board might be broken, requiring repair and replacement.
  • Y
    ylynchAug 25, 2025
    Why is there no cool wind in DRY mode on my MAXA N-P35A2 Air Conditioner?
    • J
      James TuckerAug 25, 2025
      If there is no cool wind in DRY mode on your MAXA Air Conditioner, the evaporator may be frosting. The unit will run in defrosting operation and resume normal operation after defrosting.

Summary

SAFETY INFORMATION

Remote Control Operation

Setting Operating Modes and Fan Speed

How to select modes (Cool, Heat, Fan, Dry, Auto) and adjust fan speed.

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Unit Installation: Location and Placement

Window Installation: Double-Hung Sash

Step-by-step guide for installing the unit in a double-hung sash window.

Window Installation: Sash Types

Double-Hung Sash Window Fitting

Detailed steps for double-hung sash window installation.

Sliding Sash Window Fitting

Detailed steps for sliding sash window installation.

Window Installation: Sliding Sash Details

Exhaust Hose Assembly and Components

CARE AND MAINTENANCE

TROUBLESHOOTING

Unit Not Starting or Cooling Issues

Solutions for when the unit won't start or fails to cool effectively.

LED Error Codes and Water Tank Issues

Explains error codes (E, H8, F1, F2, F4) and water tank full messages.

MAXA N-P35A2 Specifications

General IconGeneral
Cooling Capacity12000 BTU/h
Power Supply220-240V, 50Hz
EER3.21
Coefficient of Performance (COP)3.61
RefrigerantR410A
Air Flow (Indoor)550 m³/h
Weight (Outdoor Unit)28 kg
TypeSplit
Cooling Power3500 W
Energy Efficiency Ratio (EER)3.21
Noise Level42 dB
Noise Level (Outdoor)52 dB
Noise Level (Indoor)42 dB(A)