omron E3K-R10K4 wiring for max pro
Polarity does NOT matter
12VDC Out Monitored
4 5 6
C-1 NO1 NC1
LIGHT ON
SENSITIVITY
Min Max
DARK ON
Power
Set switch to
“LIGHT ON”
24 to 240 VAC
24 to 240 VDC
1 2
N02 C2
3
Sensitivity Adjustment:
If the photocell does not respond to an
obstruction, lower the sensitivity by
turning adjustment counter-clockwise.
OK to
use
12VDC
PHOTO CLS NC
GND
NOTE: To meet the UL 325 2018 standard,
Type B1 Non-Contact sensor entrapment
protection device MUST be MONITORED
by the gate operator.
NORMALLY CLOSED (NC)
UL325-2018
Wiring to E3K Photocell
DO NOT connect
to NC2 #4.
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
UL SENSOR N.C.UL SENSOR 10K
NSOR N.C
P
NSOR N.C
P
SOR N.
P
SOR N
P
SOR N
SOR N
OR N
OR N
OR
NC2 N02 C2
IMPORTANT:
Photocell MUST be powered
by 12VDC OUT Monitored or
it will NOT be MONITORED.
For 10K Resistor E3K Photocell wiring see next page
UL 2018 Label on packaging
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7d
Polarity does NOT matter
12VDC Out Monitored
4 5 6
C-1 NO1 NC1
LIGHT ON
SENSITIVITY
Min Max
DARK ON
Power
Set switch to
“LIGHT ON”
24 to 240 VAC
VDC24 to 240
1 2
N02 C2
3
Sensitivity Adjustment:
If the photocell does not respond to an
obstruction, lower the sensitivity by
turning adjustment counter-clockwise.
OK to
use
12VDC
OPEN ONLY NC
GND
NOTE: To meet the UL 325 2018 standard,
Type B1 Non-Contact sensor entrapment
protection device MUST be MONITORED
by the gate operator.
Installation Steps:
1. Set switch to “LIGHT ON”
2.
3.
Wire 12V power to photocell
Wire OPEN ONLY NC
to photocell NO2
Wire GND to photocell C2
4. Align photocell to reflector
5. Adjust sensitivity
UL325-2018
NORMALLY CLOSED (NC)
Wiring to E3K Photocell
DO NOT connect
to NC2 #4.
NC2 N02 C2
IMPORTANT:
Photocell MUST be powered
by 12VDC OUT Monitored or
it will NOT be MONITORED.
For 10K Resistor E3K Photocell wiring see next page
UL 2018 Label on packaging
23
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
UL SENSOR 10K
UL SENSOR N.C.
Installation Steps:
1. Set switch to “LIGHT ON”
2.
3.
Wire 12V power to photocell
Wire PHOTO CLS NC
to photocell NO2
Wire GND to photocell C2
4. Align photocell to reflector
5. Adjust sensitivity
CLOSING Direction
Photocell (Reflector)
OPENING Direction
Photocell (Reflector)