11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
20
GRAVITY DOWN LIFTGATES
1. Lower platform to ground. Remove
drain plug (FIG. 20-1). Drain hydraulic
fl uid from system. Reinstall drain plug.
GRAVITY DOWN PUMP & MOTOR
FIG. 20-1
2. Unscrew breather cap (FIG. 20-1)
and refi ll reservoir with hydraulic fl uid to
level shown in FIG. 20-1. Reinstall breather
cap (FIG. 20-1).
3. Stow the Lift and do the CHECKING HY-
DRAULIC FLUID procedure in this section
of the manual.
2. Disconnect the white wire (FIG. 20-2) from
starter solenoid. Lower the platform while
draining the remaining hydraulic fl uid from sys-
tem. Reinstall drain plug. Reconnect the white
wire to starter solenoid.
1. Open and raise platform to vehicle bed height.
Remove drain plug (FIG. 20-1). Drain hydraulic
fl uid.
POWER DOWN LIFTGATES
3. Remove breather cap (FIG. 20-1) and
refi ll reservoir with hydraulic fl uid to level
shown in FIG. 20-1. Reinstall breather
cap (FIG. 20-1).
4. Stow the Lift and do the CHECKING HYDRAULIC
FLUID procedure in this section of the manual.
POWER DOWN PUMP
FIG. 20-2
WHITE
WIRE
STARTER
SOLENOID
BREATHER
CAP
RESERVOIR
DRAIN PLUG
HEX NUT
CHANGING HYDRAULIC FLUID - Continued
PERIODIC MAINTENANCE - Continued