47
LIFTGATE WILL NOT LIFT RATED CAPACITY
1. Lower platform to the ground. See OPERATION
MANUAL.
2. Use voltmeter to verify the battery voltage is a
minimum 10.5 volts DC, or 21 volts DC for a 24
volt system, under load from pump motor.
POWER UNIT FLUID LEVEL
FIG. 47-1
3. Check the hydraulic fl uid level in reservoir as
follows. With platform on the ground, fl uid level
should be as shown in FIGS. 47-1.
RESERVOIR