44
PLATFORM RAISES PARTIALLY AND STOPS
TROUBLESHOOTING - Continued
1. Lower platform to the ground. See OPERATION
MANUAL.
2. Use voltmeter to verify the battery voltage is a
minimum 10.5 volts DC, or 21 volts DC for a 24
volt system, under load from pump motor.
3. Check the hydraulic fl uid level in reservoir as
follows. With platform on the ground, fl uid level
should be as shown in FIGS. 44-1.
POWER UNIT FLUID LEVEL
FIG. 44-1
RESERVOIR