Extended AT Commands Manual Page 62 of 70 2009-06-25
Command
Value
per
Description
Packet
Data
+ICF IS-131
TE2-MT2 Character Framing. This extended-format compound
parameter is used to determine the local serial port start-stop
(asynchronous) character framing that the MT2 shall use while
accepting TE2 command set and while transmitting information
text and result codes to the TE2, if this is not automatically
determined (see +IPR).
+ICF? Shows current settings
+ICF=? Shows supported range
+ICF=<format_value,parity_value> sets value
<format> valid numeric values
0 auto detect [NOT SUPPORTED]
1 8Data 2Stop
2 8Data 1Parity 1Stop
3 8Data 1Stop (Default)
4 7Data 2Stop
5 7Data 1Parity 1Stop
6 7Data 1Stop
<parity> defined numeric values
0 odd
1 even
2 Mark [NOT SUPPORTED]
3 space (Default)