Extended AT Commands Manual Page 64 of 70 2009-06-25
Command
Value
per
Description
Packet
Data
+IPR IS-131
Fixed Rm Rate. This numeric extended-format parameter specifies
the data rate at which the MT2 will accept command set, in
addition to 1200 bit/s or 9600 bit/s (as required in EIA/TIA-602).
It may be used to select operation at rates at which the MT2 is not
capable of automatically detecting the data rate being used by the
TE2.
115200bps. (Default)
+IPR? Displays current set value.
+IPR=? Displays range of (supported autodetectable rates), (list of
supported fixed-only rates). e.g. +IPR: (1200, 2400, 4800, 9600,
19200), (45, 50, 75, 110, 150, 300, 600, 38400, 57600, 115200,
230400)
+IPR=<value> Set value
E
: Chan
g
es to +IPR rate are written to default NV memory in F0 profile independent of
the &W command. Use &W command to write +IPR changes to F1-5 user profiles.