Domino’s RA-45 Schematics and Troubleshooting
  289905-01-200
M-21-08 REV. A 
 
Page 29 of 36     
  Hydraulic Hose Fitting Torque & Electrical Values, Power Unit 
   
Coil Resistance:  5.4Ω @70ºF. ±15% 
Ampere: (Across #10 coil terminal studs) 
2.2A @ 12.5V 
#10 Coil terminal torque:    10-15 lb.-in max. 
5/16” Contact terminal torque:    30-35 lb.-in max. 
Hyd. Solenoid Valves (SV1) 
Coil Resistance: (Across male quick connects) 
4.0Ω @ 70ºF. ±15% 
Ampere: 
3.1A @ 12.5V / 2.5A 
 Coil nut torque:       15-45 lb-in 
 Valve cartridge torque:      25-30 lb.-ft max. 
Hyd. Sol. Lock Valves (SV2, SV3, SV4) 
8.0Ω @ 70ºF. ±15% 
Ampere: 
1.5A @ 12.5V 
Coil nut torque:         3-4.5 lb-ft 
Valve cartridge torque:       18.5-22 lb-ft max. 
Coil Resistance: (Across terminals 85 & 86)  90Ω @70ºF. ±10% 
Ampere: 
133mA @ 12V 
  Motor Starter Switch    Hyd. Solenoid Lock Valve 
         
 
Contact