Domino’s RA-45 Schematics and Troubleshooting
  289905-01-200
M-21-08 REV. A 
 
Page 35 of 36     
2.  SV3 (in) valve not shifting. 
SV1 & SV3 (out) valves not shifting. 
Check electrical connections at valve. 
Remove and clean valve if needed. 
Adjust in/out pressure relief valves. 1800 psi for 
out, 2400 psi for in. 
4.  Damaged/worn roller bearing. 
With platform at the “out” position check if Load 
Finger is not resting Rail Stop.  This is sign roller 
bearing wear. 
 
Replace rollers. 
Platform not going up or down, 
motor runs. 
 
 
 
 
 
 
 
 
1.  Battery voltage low. Solenoids not 
activating. 
Tighten power and ground connections.  Charge 
batteries and check charging system. 
Battery voltage should be > 12.2 V. 
2.  SV2 valve not shifting. 
Check controller S2 term. voltage. Should be >10v. 
 
Check electrical connections at valve. 
Remove and clean valves if needed.